|
Young Hwan Jo, DDS, MSD, PhD,a Peter K. Hobo, DDS,b and Sumiya Hobo, DDS, MSD, PhDc Seoul Dental Institute, Seoul, Korea, and International Dental Academy, Tokyo, Japan
Two hundred eighty-six immediate-load Sargon® implants were placed in 75 patients during a 40-month period. Of the 273 implants that survived, 81 were placed into fresh extrac tion sockets and immediately loaded, 162 were placed into healed sites and immediately loaded, and 30 were delay loaded. Some implants that had failed to remain stable after immediate loading became stable and osseointegrated after the load was removed and their expansion mechanisms were reactivated.
| Purpose. The purpose of this study was to evaluate the effectiveness of an expandable implant design for immediate and delayed loading and for freestanding and multiunit situations. Material and methods. Two hundred eighty-six immediate-load Sargon® implants were placed in 75 patients during a 40-month period. Of the 273 implants that survived, 81 were placed into fresh extrac tion sockets and immediately loaded, 162 were placed into healed sites and immediately loaded, and 30 were delay loaded. Some implants that had failed to remain stable after immediate loading became stable and osseointegrated after the load was removed and their expansion mechanisms were reactivated. Results. The overall survival rate during the 40-month period was 96.0% in the maxilla and 94.8% in the mandible. Implants placed in fresh extraction sockets showed a 98.9% survival rate. Healed sites showed a 93.9% survival rate. Immediate loading of 52 fresh extraction socket implants in the maxilla showed a 100% survival rate during the evaluation period. aft Conclusion. Within the limitations of this study, it was shown that the feature of mechanical expand ability may provide operators some control over implant stability during the vulnerable period after immediate loading of single, freestanding implants. (J Prosthet Dent 2001;85:148-55.) aDirector, Seoul Dental Institute. bStaff, International Dental Academy. cDirector, International Dental Academy.
| CLINICAL IMPLICATIONS Enhancing the stability of immediately placed, freestanding implants by expandin8 the implant over a 21-day period may improve the prognosis for immediate loading. |
| The concept of osseointegrafon, as described by Branemark,1 has drastically improved the reliability of dental implants and changed the nature of clinical practice. To achieve successful osseointegration, a patient must wait 8 to 12 months for ossification of an extraction socket, followed by healing periods of 3 to 6 months after the placement of an implant. This treatment sequence is known as the 2-stage submerged procedure.2,3 However, this procedure is no longer necessary to achieve osseointegrafon, because 1-stage nonsubmerged procedures4-12 and immediate-implant placements have shown good clinical results.13-25 Recently, the immediate loading of implants on placement has drawn the attention of dentists.26-36 Tarnow et al37 reported that when multiple implants were placed and splinted into a full-arch form and immediately loaded, favorable results were obtained. Branemark38 also reported a method to place multiple implants into the mandibular anterior region by using a special template to place the superstructure to perform immediate loading. To date, there are no scientific reports to indicate predictable immediate loading on a single-tooth, freestanding implant. Predictable immediate loading can fulfill a number of requirements not currently addressed by traditional implants. First and foremost is the ability to extract a diseased tooth in the esthetic zone and immediately replace it with a provisional restoration in full function and esthetic form (provided that no orthodontic, periodontic, or endodontic corrective treatments are required within the region or on adjacent teeth). Preservation of papillary anatomy and the emergence profile could be accomplished easily if fresh extraction sockets could be implanted and immediately loaded with correctly contoured provisional restorations. Moreover, immediate loading of fresh extraction sockets could preserve dental arch integrity, occlusion, and patient satisfaction, especially in single-tooth, freestanding situations | 148 THE JOURNAL OF PROSTHETIC DENTISTRY VOLUME 85 NUMBER 2 | Table I. Number of implants (total n = 286) and length of evaluation period after placement. Number of implants
| Evaluation period (mo)
| 20 | 13 | 8 | 16 | 50 | 22 | 96 | 28 | 48 | 34 | 64 | 40 |
| It seems that implants will continue to evolve until a reliable, immediately loadable implant system is perfected. Variations in implant designs (in thread configurations, surface characteristics,39-4t and expandability42) have been introduced to obtain immediate loadability. One manufacturer (Sargon Enterprises, Inc, Beverly Hills, Calif.) has claimed that because its implant has an expandable design, it allows immediate loading of a single-tooth implant after placement in both fresh extraction sockets and healed sites. The purpose of this study was to evaluate the effectiveness of this expandable implant under immediate- and delayed-loading conditions. Other clinical conditions, such as freestanding and multiunit cases in fresh extraction sockets and healed sites, were included. MATERIAL AND METHODS A total of 286 Sargon immediate load implants (hereafter referred to as "expandable implants") were placed in 75 patients. The patient group included 42 men and 33 women ranging in age from 20 to 71 years, with a mean age of 49 years. All patients selected were in good general and oral health. None of the subjects exhibited subjective or objective complications during the surgical operation. The number of implants and the evaluation period after placement are shown in Table I. All patients were selected solely on the basis of bone volume adequate for implant placement. None of the patients were rejected because of any pretreatment assumptions of poor bone quality or because they used tobacco. Bone quality was determined after each implant was placed and expanded by using the implant as a bone compaction device.42 No patients were rejected after they entered into this study, and all patients were treated consecutively. Preoperative occlusal and radiographic evaluations were made, and any deficiencies or pathologies were corrected before surgery. This included any necessary endodontic treatment for adjacent teeth and periodontal therapy. No pretreatment orthodontic socket corrections were performed. 
Expandable implants were placed under 2 different conditions: fresh extraction sockets and healed sites. All extractions were performed with an effort to avoid fracture of facial and crestal bone and to preserve the soft tissue of the crestal region. To place the expandable implant into a fresh extraction socket, a channel was bored into the bone with a series of drills, then tapped manually. The channel was made in a trajectory that provided the greatest volume of bone around the implant. Attention was given to submerging the implant at least 5 MM23 apical to the cementoenamel junctions of the adjacent teeth with 75% of the implant's surface42 within bone. The expandable implant used in this study has a quintapodal design in the apical half of the body, which is divided into 4 legs that can expand with the turn of a central expansion screw that becomes the fifth leg (Fig. 1). There are 3 different lengths (10, 13, and 16 mm) that can expand from the original diameter of 3.8 mm to a maximum of 5.5, 6.8, and 6. 8 mm, respectively. The expansion screw is turned with a screwdriver by using only finger-wrist force until definite resistance from the surrounding bone can be felt. When an implant was placed into a fresh extraction socket, the vertical position of the collar was approximately 1 to 2 mm below the interproximal crestal height. Neither grafting techniques nor barrier membranes were used to compensate for the gap between the cervical form of the expandable implant and the crestal walls of the extraction socket. Provisional restorations were fabricated immediately after placement of the implants and were seated within the same appointment (Figs. 2 through 6). When bone-contacting surface areas were limited or bone quality was poor, delayed loading was used, and implant heads were covered with healing collars to preserve optimum tissue contour. Three months after implant placement, a final restoration was placed. | 149 THE JOURNAL OF PROSTHETIC DENTISTRY VOLUME 85 NUMBER 2 | 
Fig. 2. Extraction of maxillary right central incisor. | 
Fig. 3. Implant placement. | 
Fig. 4. Provisional restoration. Note emergence profile and long axis. | 
Fig. 5. Labial view of provisional restoration. | 
Fig. 6. Radiograph of implant replacing maxillary right central incisor. |
| | This treatment sequence was called "delayed loading" as opposed to "immediate loading." In both situations, the occlusion of the restoration was carefully established.43 The implant was used as a bone-quality evaluation instrument to indicate loading ability (Table II). | This method was used to predict the ability to load immediately. Regardless of whether immediate or delayed loading was performed, the stability (micromobility) of the implants was examined with the postoperative protocol suggested by Lazarof et a142 (Table II) at 7-day intervals for 21 days. | 150 THE JOURNAL OF PROSTHETIC DENTISTRY VOLUME 85 NUMBER 2 | Table II. Stability test outcomes and treatments for postoperative follow-ups within 3 weeks
| Clinical tests positive for instability
| Clinical tests negative for instability
| | First week | Remove provisional and expand further | No treatment | | Second week | Remove provisional and expand further | No treatment | | Third week | Remove provisional and wait 16 to 18 weeks | No treatment Observe and proceed |
|
Table III. Placed and failed (in parentheses) implants: Immediate loading in fresh extraction sockets
| Maxilla
| Mandible
| | 10 mm | 1 (0) | 7 (1) | | 13 mm | 26 (0) | 17 (0) | | 16 mm | 25 (0) | 6 (0) | | Total | 52 (0) | 30 (1) |
|
Table IV. Placed and failed (in parentheses) implants: Delayed loading in fresh extraction sockets
| Maxilla
| Mandible
| | 10 mm | 2 (0) | 0 (0) | | 13 mm | 3 (0) | 0 (0) | | 16 mm | 3 (0) | 0 (0) | | Total | 8 (0) | 0 (0) |
|
Table V. Placed and failed (in parentheses) implants: Immediate loading in healed sites
| Maxilla
| Mandible
| | 10 mm | 9 (1) | 20 (1) | | 13 mm | 26 (2) | 44 (3) | | 16 mm | 32 (0) | 33 (1) | | Total | 67 (3) | 97 (5) |
|
The criteria used to test for stability were as follows: (1) percussion sounds from a metal instrument, (2) percussion and pressure sensitivity, (3) observation of mobility after application of lateral force, and (4) ability to easily turn the expansion screw clockwise. Only those implants that did not test clinically stable during the 21-day period after placement were given additional expansion. If any stability tests were positive, the expansion mechanism within the implant was reactivated until firm bony resistance was observed, after which loading was continued. For immediately loaded implants that exhibited positive testing more than 2 times during the 3-week testing period, all loads were removed for 16 to 18 weeks, after which the provisional restorations were placed back onto the implant. | Table VI. Placed and failed (in parentheses) implants: Delayed loading in healed sites
| Maxilla
| Mandible
| | 10 mm | 4 (3) | 3 (1) | | 13 mm | 16 (0) | 4 (0) | | 16 mm | 5 (0) | 0 (0) | | Total | 25 (3) | 7 (1) |
|
Table VII. Placed and failed (in parentheses) single-tooth, freestanding implants
| Fresh extraction socket
| Healed site
| | Immediate loading | 29 (0) | 36 (3) | | Delayed loading | 4 (0) | 4 (1) | | Total | 33 (0) | 40 (4) |
|
Table VIII. Placed and failed (in parentheses) implants according to the number of implants in the multiunit situation
| Number of cases
| Number of implants placed
| | 2 implants | 16 (1) | 32 (1) | | 3 implants | 29 (1) | 87 (1) | | 4 or more implants | 19 (0)* | 94 (7) | | Total | 64 (2) | 213 (9) |
| *Implants were lost but nonetheless restorable without placing additional implants. |
RESULTS Of the 286 implants, 90 were placed into fresh extraction sockets, 82 of those underwent immediate loading, and the remaining 8 underwent delayed loading. The results are shown in Tables III and IV. One hundred ninety-six implants were placed into healed sites; 164 of those underwent immediate loading, and the remaining 32 underwent delayed loading. The results are shown in Tables V and VI. Of all implants placed, 73 were freestanding, single-tooth replacements, and 213 were multiunit. The results are shown in Tables VII and VIII. The postoperative protocol for expandable implants suggests additional expansion for reestablishing intimate bone contact. The number of implants that received additional expansion was 208. The loss of stability after loading may suggest insufficient expansion during initial implant placement. Complications such as fistula formation and crestal bone loss, structural problems such as bacterial leakage at the abutment-implant interface, and mobility may contribute to implant instability. Four categories of complications and their distributions are shown in Table IX. | 151 THE JOURNAL OF PROSTHETIC DENTISTRY VOLUME 85 NUMBER 2 |
Fig. 7. Radiograph of mild bone loss limited above first and second thread. |
Fig. 8. Radiograph of severe cratering extended at furcation area. |
Fig. 9. Radiograph of radiolucency around furcation area. |
In this investigation, a total of 13 implants failed because of such complications and/or additional, unknown factors. Table IX. Complications relative to the expandable implant Incidents
| Number of occurrences
| Number of recoveries
| Number of failures
| | Fistula formation | 10 | 10 | 0 | | Crestal bone loss | 35 | 0 | 4 | | Mobility | 17 | 4 | 13 | | Bacterial contamination | 3 | 3 | 0 |
|
Table X. Survival rate based on loading
| Maxilla
| Mandible
| | Immediate load Fresh extraction socket | 100% | 96.7% | | Healed site | 95.5% | 94.8% | | Delayed load Fresh extraction socket | 100% | --- | | Healed site | 88% | 85.7% |
|
Ten fistulas, apparently caused by residual cysts and root remnants, were found in this study. These were resolved after removal of the pathosis. Among these, 2 fistulas were associated with leakage, and it was necessary to seal the central abutment channel and remove pathologic agents to resolve them. Thirty-five implants exhibited crestal bone loss. Among these, 29 implants showed mild bone loss limited above the first or second thread (Fig. 7). However, 6 implants showed severe, crater-like bone resorption that extended to the furcation area (Fig. 8). In all 6 cases, the implants were fully expanded, which suggested type IV bone quality. Among these, 4 filed and 2 were salvaged by removing the load for 16 to 18 weeks. Seventeen implants exhibited mobility. Among these, with additional expansion and removal of the load for 16 to 18 weeks, 4 implants recovered. The remaining 13 implants failed. Four of them had mobility with severe, crater-like bone resorption. Three implants showed a 2 to 3 mm radiolucency around the fiircation area (Fig. 9). This tray be attributable to bacterial leakage from a defective expansion screw mechanism. After sealing the top of the expansion screw with the delrin sealing cap and a composite resin luting cement, all radiolttcelicies disappeared, and the implants recovered. The survival rates of the 286 implants were surveyed under loading conditions of immediate loading and delayed loading (Table X). An example of delayed loading of a mandibular fresh extraction socket was not performed. The overall survival rate of the expandable implants up to a 40-month period was 96.0% in the maxilla and 94.8% in the mandible. | 152 THE JOURNAL OF PROSTHETIC DENTISTRY VOLUME 85 NUMBER 2 | DISCUSSION Contemporary trends for the immediate loading of individual, freestanding implants suggest that ideal conditions of bone and patient cooperation are vital. This study indicates that those parameters may be expanded. Delayed loading was performed only in type IV bone. It was found that fresh extraction sockets exhibited results superior to those of healed sites. Contrary to reports in the dental literature involving traditional implants, results in the maxilla were more favorable than in the mandible. Although the 286 implants used in this study were assumed to be an adequate sample, the evaluation period of up to 40 months is not long enough to derive a general conclusion. Other studies now in progress involving the expandable implant may offer more information to support the results of this study. The survival rates of immediately loaded and delay loaded implants were 96.3% and 90%, respectively. The more favorable result for immediate loading is assumed to be due to the strong anchoring effect, which occurs with expansion of the implant. Brunski44,45 stated that micromotion of more than 100 µm must be avoided to achieve successful osseointegration. Apparently, the compaction of the quintapodal legs into bone by apical expansion effectively prevented micromotion of the implant. With apical expansion, a compressive force is produced that causes a microfracturing of the periapical trabecular bone. It may be that, with immediate loading, an intermittent stimulus occurs during function. Either of these 2 factors might be effective in inducing bone formation and thus responsible for the favorable results produced by immediate loading. The implants placed in fresh extraction sockets showed a survival rate of 98.9%, whereas those placed in healed sites had a survival rate of 93.9%. Fresh extraction sockets exhibited slightly superior results in these patients. Because most fresh extraction sockets are classified into type II bone, they are suitable for placing implants. It is known that metabolism is more active in the bone of fresh extraction sockets than in the bone of healed sites.46,47 This factor may have contributed to the favorable results obtained in this study. Moreover, in the orthodontically correct fresh extraction socket, the implant can be placed within the original dental arch, and occlusal forces can be transmitted in the direction of the long axis of the implant. The traditional sequence of therapy calls for tooth extraction and healing to occur before implant placement. This method permits the alveolar ridge to collapse and bone quantity and quality to diminish, through disuse, to such a point that it may not be possible to place implants without the additional time and expense of grafting procedures. For this reason, it would seem more desirable for implants to be placed in fresh extraction sockets rather than in healed sites. Single-tooth freestanding conditions and multiunit conditions were compared. The survival rate of single- tooth, freestanding implants was 94.5%, whereas the survival rate of multiunit cases was 96.9%. This result suggests that the single-tooth, freestanding condition was quite promising, particularly in fresh extraction sockets in the maxilla, where the survival rate was 100%. In the past, immediate loading was possible only when multiple implants were placed and splinted. This study indicates that the immediately loaded, single-tooth, freestanding implant has a high survival rate when the expandable implant is used. The fact that implant placement into fresh extraction sockets showed a result superior to that reported by traditional implants is an indication that additional studies that make use of the expandable implant are needed. Treatment planning concepts for esthetic implants, as they pertain to the timing of tooth extractions and placement of implants, may need to be altered. Of the 286 implants placed, 208 recorded a positive response to the stability test and underwent additional expansion. A positive response indicated the occurrence of micromotion, which was eliminated by additional expansion. Seventy-five implants exhibited complications. Because 6 implants combined more than 1 complication, the actual number of complications was 69, none of which were the result of mechanical failure (fracture) of the implants. Among these, 13 implants failed. They were removed by simply reversing the expansion mechanism and allowing the implant to collapse. The majority of the complications were problems common to all implants (for example, failure to integrate possibly because of frequent tobacco use, biomechanics, and systemic conditions). The 2- to 3-mm-wide radiolucencies in the furcation area on 3 of the implants completely resolved after cementation of the delrin seal cap for the internal screw head located at the bottom of the abutmentscrew channel. This reversal strongly indicates that bacteria-laden oral fluids were able to pass through the seal mechanism of some of these implants and into the bone, causing the lesions. Possible causes of the leakage include insufficient expansion-screw tightening on placement of the implant and manufacturing defects. The ability to rescue an implant that has developed micromotion by performing additional expansion is a beneficial feature of the expandable implant. Without this feature, the results of this study would not have been as favorable. | 153 THE JOURNAL OF PROSTHETIC DENTISTRY VOLUME 85 NUMBER 2 |
CONCLUSIONS On the basis of this evaluation of 286 expandable, immediate load implants placed into 75 patients during a 40-month period, the following conclusions were drawn. - Survival rates of 100% in the maxilla and 96.7% in the mandible were obtained by immediate loading in fresh extraction sockets.
- Survival rates of 95.5% in the maxilla and 94.8% in the mandible were obtained by immediate loading in healed sites.
- The overall survival rates were 96.0% in the maxilla and 94.8% in the mandible.
- The results suggest that, even if instability occurs after initial loading, removal of the occlusal load for 16 to 18 weeks and additional expansion can restabilize the implant.
- Because this was a 40-month serial case study, the results are limited and should be viewed with reservation until a 60-month (or longer) evaluation is
performed.
REFERENCES 1. Branemark PI, Adell R, Breine U, Hansson BO, Lindstrom J, Ohlsson A. Intra-osseous anchorage of dental prostheses. I. Experimental studies. Scand J Plast Reconstr Surg 1969;3:81-100.2. Branemark PI, Hansson BO, Adell R, Breine U, Lindstrom J, Hallen O, et al. Osseointegrated implants in the treatment of the edentulous jaws. Experience from a 70-year period. Scand J Plast Reconstr Surg Suppl 1977;16:1-132.3. Branemark PI, Zarb GA, Albrektsson T, editors. Tissue-integrated prosthe ses: osseointegration in clinical dentistry. Chicago: Quintessence; 1985. 4. Schroeder A, van der Zypen E, Stich H, Sutter F. The reaction of bone, connective tissue, and epithelium to endosteal implants with titanium sprayed surfaces. J Maxillofac Surg 1981;9:15-25.5. Schroeder A, Maeglin B, Sutter F. ITI (Internationales Team fur orate Implantologie) type-F hollow cylinder implant for denture retention in the edentulous jaw. [German] SSO Schweiz Monatsschr Zahnheilkd 1983;93:720-33. 6. Babbush CA, Kent JN, Misiek DJ. Titanium plasma-sprayed (TPS) screw implants for the reconstruction of the edentulous mandible. J Oral Maxillofac Surg 1986;44:274-82. 7. Buser DA, Schroeder A, Suttee P, Lang NP. The new concept of ITI hol low-cylinder and hollow-screw implants: part 2. Clinical aspects, indications, and early clinical results. Int J Oral Maxillofac Implants 1988;3:173-81. 8. Buser D, Weber HP, Lang NP. Tissue integration of non-submerged implants: 1-year results of a prospective study with 100 ITI hollow- 32. cylinder and hollow-screw implants. Clin Oral Implants Res 1990;1 :33 40. 9. ten Bruggenkate CM, Muller K, Oosterbeek HS. Clinical evaluation of the ITI (F-type) hollow cylinder implant. Oral Surg Oral Med Oral Pathol 1990;70:693-7.10. Ericsson I, Randow K, Glantz PO, Lindhe J, Nilner K. Clinical and radi ographic features of submerged and nonsubmerged titanium implants. Clin Oral Implants Res 1994;5:185-9. 11. Ericsson I, Randow K, Nilner K, Petersson A. Some clinical and radi ographical features of submerged and non-submerged titanium implants. A 5-year follow-up study. Clin Oral Implants Res 1997;8:422-6. 12. Collaert B, de Bruyn H. Comparison of Branemark fixture integration and short-term survival using one-stage or two-stage surgery in completely and partially edentulous mandibles. Clin Oral Implants Res 1998;9:131-5.13. Barzilay I, Graser GN, Caton J, Shenkle G. Immediate implantation of pure titanium threaded implants into extraction sockets. J Dent Res 1988;67:234-40. 14. Lazzara RJ. Immediate implant placement into extraction sites: surgical and restorative advantages. Int 1 Periodontics Restorative Dent 38. 1989;9:332-43. 15. Barzilay I, Graser GN, Iranpour B, Natiella JR. Immediate implantation of a pure titanium implant into an extraction socket: report of a pilot pro- cedure. Int J Oral Maxillofac implants 1991;6:277-84.16. Becker W, Becker BE, Handelsman M, Ochsenbein C, Albrektsson T. Guided tissue regeneration for implants placed into extraction sockets: a study in dogs. J Periodontol 1991;62:703-9. 17. Knox R, Caudill R, Meffert R. Histologic evaluation of dental endosseous implants placed in surgically created extraction defects. Int J Periodontics Restorative Dent 1991;11:364-75. 18. Becker W, Becker BE, Ochsenbein C. The use of guided tissue regeneration for implants placed in immediate extraction sockets. Tissue integration in oral, orthopedic, and maxillofacial reconstruction. Chicago: Quintessence; 1992. p. 200-2. | 19. Gelb DA. Immediate implant surgery: three-year retrospective evaluation of SO consecutive cases. Int J Oral Maxillofac Implants 1993;8:388-99.20. Lang NP, Bragger U, Hammerle CH. Sutter F. Immediate transmucosal implants using the principle of guided tissue regeneration. I. Rationale, clinical procedures and 30-month results. Clin Oral Implants Res 1994;5:154-63.21. Becker W, Dahlin C, Becker BE, Lekholm U, van Steenberghe D, Higuchi K, et al. The use of e-PTFE barrier membranes for bone promotion around titanium implants placed into extraction sockets: a prospective multicenter study. Int J Oral Maxillofac Implants 1994;9:31-40.22. Mensdorff-Pouilly NM, Haas R, Mailath G, Watzek G. The immediate implant. A retrospective study comparing the different types of immediate implantation. Int J Oral Maxillofac Implants 1994;9:571-8.23. Rosenquist B, Grenthe B. Immediate placement of implants into extraction socket: implant survival. Int J Oral Maxillofac Implants 1996;1 1 :205-9.24. Hammerle CH, Bragger U, Schmid B, Lang NP. Successful bone formation at immediate transmucosal implants: a clinical report. Int J Oral Maxillofac implants 1998;13: 522-30.25. Grunder U, Polizzi G, Goene R, Hatano N, Henry P, Jackson WJ, Kawamura K, et al. A 3-year prospective multicenter follow-up report on the immediate and delayed-immediate placement of implants. Int J Oral Maxillofac Implants 1999;14:210-6.26. Schnitman PA, Wohrle PS, Rubenstein JE. Immediate fixed interim prostheses supported by two-stage threaded implants: methodology and results.) Oral Implantol 1990;16:96-105.27. Linkow LI, Donath K, Lemons JE. Retrieval analyses of a blade implant after 231 months of clinical function. Implant Dent 1992;1:37-43.28. Wohrle PS, Schnitman PA, DaSilva JD, Wang N-H, Koch GG. Branemark implants placed into immediate function: 5-year results [abstract]. J Oral Implant 1992;18:382.29. Sagara M, Akagawa Y, Nikai H, Tsuru H. The effects of early occlusal loading on one-stage titanium alloy implants in beagle dogs: a pilot study. J Prosthet Dent 1993;69:281-8.30. Henry P, Rosenberg I. Single-stage surgery for rehabilitation of the edentulnus mandible: preliminary results. Pract Periodontics Aesthetic DenJ 1994;6:15-22; quiz 24.31. Schnitman PA. Branemark implants loaded with fixed provisional prostheses at fixture placement: nine-year follow-up. J Oral Implantol 1995;21:235. 32. Salama H, Rose LF, Salama M, Betts NJ. Immediate loading of bilaterally splinted titanium root-form implants in fixed prosthodontics-a technique reexamined: two case reports. Int J Periodontics Restorative Dent 1995;15:344-61.33. Balshi TI, Wolfinger GJ. Immediate loading of Branemark implants in edentulous mandible: a preliminary report. Implant Dent 1997;6:83-8.34. Schnitman PA, Wohrle PS, Rubenstein JE, DaSilva JD, Wang NH. Tenyear results for Branemark implants immediately loaded with fixed prostheses at implant placement. Int J Oral Maxillofac Implants 1997;12:495-503.35. Randow K, Ericsson I, Nilner K, Petersson A, Glantz PO. Immediate functional loading of Branemark dental implants. An 18-month clinical follow-up study. Clin Oral Implants Res 1999;10:8-1 S.36. Zubery Y, Bichacho N, Moses O, Tal H. Immediate loading of modular transitional implants: a histologic and histomorphometric study in dogs. Int J Periodontics Restorative Dent 1999;19:343-53.37. Tarnow DP, Emtiaz S, Classi A. Immediate loading of threaded implants at stage 1 surgery in edentulous arches: ten consecutive case reports with 1- to 5-year data. Int ) Oral Maxillofac Implants 7997;12:319-24.38. Branemark PI, Engstrans P, Ohnell LO, Grondahl K, Nilsson P, Hagberg K. Branemark Novum: a new treatment concept for rehabilitation of the edentulous mandible. Preliminary results from a prospective clinical follow-up study. Clin Implant Dent Related Res 1999;1:2-16.39. Klokkevold PR, Nishimura RD, Adachi M, Caputo A. Osseo integration enhanced by chemical etching of the titanium surface. A torque removal study in the rabbit. Clin Oral Implants Res 1997;8:442-7. 40. Sullivan DY, Sherwood RL, Mai TN. Preliminary results of a multicenter study evaluating a chemically enhanced surface for machined commercially pure titanium implants. J Prosthet Dent 1997;78:379-86.41. Lazzara RJ, Porter SS, Testori T, Galante J, Zetterqvist L. A prospective multicenter study evaluating loading of osseotite implants two months after pkacement. one-year results. J Estfnet Dent 1998;10:280-9. | 154 THE JOURNAL OF PROSTHETIC DENTISTRY VOLUME 85 NUMBER 2 | | 42. Lazarof S, Hobo S, Nowzari H. The immediate load implant system.Tokyo: Quintessence; 1998. p. 60-2. 43. Hobo S, Jo YH. Occlusion for the osseointegrated prosthesis. J Gnathol 44. Brunski 18. Biomechanical factors affecting the bone-dental implant interface. [Review) Clin Mater 1992;10:153-201. 45. Brunski JB. Avoid pitfalls of overloading and micromotion of intraosseous implants. Dent Implantol Update 1993;4:77-81. 46. Bessho K, Tagawa T, Murata M. Purification of rabbit bone morpho- Dentistry. genetic protein derived from bone, dentin, and wound tissue after tooth extraction. J Oral Maxillofac Surg 1990;48:162-9. 47. NakaseT, Nomura S, Yoshikawa H, Hashimoto J, Hirota S, Kitamura Y, et al. Transient and localized expression of bone morphogenetic protein 4 messenger RNA during fracture healing. J Bone Miner Res 1994;9:651-9. | Reprint requests to: DR. Young Hwan Jo SEOUL DENTAL INSTITUTE 570-1 SINSADONG, GANGNAMGU SEOUL 135-120 1991;10:9-25. KOREA FAX: (82)2-516-4422 E-MAIL:
This email address is being protected from spam bots, you need Javascript enabled to view it
Copyright O 2001 by The Editorial Council of The Journal of Prosthetic 0022-3913/2001/$35.00 + 0. 10/1/113355 doi:10.1067/mpr.2001.113355
| Noteworthy Abstracts Current Literature | Swedish dentists' decisions on preparation techniques and restorative materials Sundberg H, Espelid, Tveit AB. Acta Odontol Scand 2000;58:135-41. | Purpose. The aim of this study was to identify variables among Swedish dentists in their choice of preparation techniques and restorative materials for the restoration of primary approximal and occlusal carious lesions in permanent teeth in an adolescent population. Material and methods. A precoded questionnaire that included illustrations of different approximal and occlusal carious lesions was sent to a random sample of 923 Swedish dentists. The sample was drawn from the register of authorized dentists and included only those dentists who were 65 years of age or younger. Of the 520 respondents, 52% were employed by the public dental health service, and 48% were in private practice. Precoded alternatives were given for both preparation type and restorative material. The responses were anonymous. The results were subject to statistical analyses. Regression analysis (ANOVA) was used to analyze the relationship between dentist age and the dependent variables of restorative techniques and choice of dental materials. Results. To restore primary approximal caries in a 20-year-old patient with low caries activity and good oral hygiene, 48% of surveyed dentists chose a tunnel preparation, 32% chose a saucer-shaped preparation, and 20% chose a traditional class II preparation. To restore occlusal caries, 74% of the respondents chose removal of the caries part only. For a mandibular second molar with a minor occlusal carious lesion combined with a suspected dentin lesion judged radiographically, 50% of the respondents chose to restore only the carious part, and 27% chose to seal the rest of the fissure system as well. For a similar lesion with no obvious dentinal radiolucency, equal numbers of respondents chose one of the following: a "no treatment" alternative, a fluoride treatment, or fissure sealing or other techniques. Resin composite was the most chosen and amalgam the least chosen material for both approximal and occlusal carious lesions. Conclusions. On the basis of the results of this survey, it seems that Swedish dentists replace traditional class II preparations with more tooth-conserving preparations. For occlusal restoration, tooth-saving techniques appear to be widely practiced, implying removal of only carious parts of the fissure system. Resin composite is the material of choice for restoration of these teeth. 23 References. -RP Renner |
| 155 THE JOURNAL OF PROSTHETIC DENTISTRY VOLUME 85 NUMBER 2 | |