Main Page arrow Research Papers arrow Bilogical Evaluation

Sargon Newsletter

Keep yourself updated with our FREE newsletters now!
Name:
Email:  Receive HTML mailings?
Subscribe
Unsubscribe

Translate This Page

Member Login

Announcements | Close

TRY YOUR FIRST SARGON® IMMEDIATE LOAD IMPLANT ON US 

SARGON® Single Tooth Replacement Kit

Introductory Price: $1,295.00

Includes 1st Implant (a $295.00 value) FREE OF CHARGE
* FOR EXPERIENCED IMPLANT USERS


SARGON® Internal Connection System Introductory Kit
 ITEM#
QTY
SURGICAL Item Description
PRICE
3913I
1

13mm STANDARD INTERNAL CONNECTION IMPLANT

$295.00
4042
1

FINAL DRILL

$145.00
4065I
1

STANDARD I.C. TAPERED FINISHING DRILL

$180.00
6040IL
1

I.C. IMPLANT DRIVER LONG

$125.00
4085
1

UNIVERSAL ONE-STEP DRILL

$180.00
6005
1

SCREWDRIVER ASSEMBLY

$85.00
6025
1

HEX DRIVER ASSEMBLY

$85.00
6055
1

HANDWRENCH

$35.00
6051
1

RATCHET

$165.00
7046G
1

I.C. IFA ABUTMENT SHORT

$165.00
7307S
1

STANDARD I.C. ABUTMENT ANALOG SHORT

$45.00
7054
1

STANDARD I.C. IFA TRANSFER SLEEVE

$30.00
9040
1

INTRODUCTORY TRAY

$55.00
    
Subtotal:
$1590.00
   
LESS:
-$295.00
(price of implant)
   
TOTAL:
$1,295.00
   

Click to Order

 
1.888.NU TOOTH

Watch Sargon Video

Bilogical Evaluation Print E-mail
Menegotto, et al. (1998) evaluated the histological aspects of the Sargon® implant. They used the standard staining techniques to indicate the location and rate of bone formation around implants. These are: 1) Goldern's stain, 2) H&E stain, 3) Calcein Green and 4) Microradiographs (Fig. 4 1 6). Their investigation showed that new bone forms on the surface of the Sargon® implant, and that a fibrous layer is not present. Moreover, the surface area that is actually osseointegrated may be much greater than the 30% that is usually seen with conventional implants due to the internal surfaces of the 5 'legs' becoming osseointegrated (the expansion screw itself becomes the 5th 'leg').

 

Recreation of Soft Tissue

 

 

Fig. 4-1 Goldern's slam is employed to detect osteoid and mineralized bone. Red portion indicates osteoid, and favorable osseointegration is suggested. (Courtesy of et al. Lewis Menegotto, University of Indiana, School of Dentistry.)

 

Fig. 4- 2 Optical microscopic photo. It is confirmed that the implant is surrounded by bone, and no soft tissue exists at the bone/implant interface. (Courtesy of et al. Lewis Menegotto, University of Indiana, School of Dentistry.)

 

Fig. 4-3 Multiple fluorochrome labeling. Bone activity is observed twice a week. The circles of bone layers are one week apart. High osteoblastic activity is suggested.
(Courtesy of et al. Lewis Menegotto, University of Indiana, School of Dentistry.)

 

Fig. 4-4 New bone is observed around the apical end of the implant. This means that microleakage is not occurring. (Courtesy of et al. Lewis Menegotto, University of Indiana, School of Dentistry.)

Fig. 4-5 Bone/implant interface. The implant is observed to be surrounded by bone. (Courtesy of et al. Lewis Menegotto, University of Indiana, School of Dentistry.)

Fig. 4-6 Specimen of the implant placed in a dog which reaches the inferior alveolar nerve. Due to the lack of sensation cause by anesthesia, the dog had been biting strongly upon the implant. The implant, however, demonstrates osseointegration. (Courtesy of et al. Lewis Menegotto, University of Indiana, School of Dentistry.)

 